Error Code E Sd
Sub PCB Communication Error — Main MICOM and Sub MICOM
Moderate
Address soon - your appliance may not work properly
What This Means
Defective Tx or Rx communication line; Defective Sub PCB; Loose connector between Main PCB and Sub PCB
How to Fix
- 1
Step 1: Check all loose connections between Main PCB and Sub PCB.
- 2
Step 2: Measure voltage at Sub CON1 pins 8-33 — expected NOT 0 or 5V; if 0 or 5V, check Sub PCB connection and if normal, replace Sub PCB.
- 3
Step 3: Measure voltage at Sub CON1 pins 10-33 — expected NOT 0 or 5V; if 0 or 5V, check Sub PCB connection and replace Sub PCB.
- 4
Step 4: Measure voltage at Main CON3 pins 1-15 — expected NOT 0 or 5V; if 0 or 5V, check Display PCB loose connection and replace Display PCB.
- 5
Step 5: Measure voltage at Main CON3 pins 3-15 — expected NOT 0 or 5V; if 0 or 5V, check Display PCB loose connection and replace Display PCB.
- 6
Step 6: If all checks are normal, explain to customer.
This Error Applies To
LG LRFOC2606 Series Refrigerators (2023) (2023–present)
Related Error Codes
Flow Meter Defect / Lack of Water Supply
Refrigerator Sensor Error
Ice Room Sensor Error or Ice Maker Sensor Error
Room Temperature Sensor Error
Freezer Cubed Ice Maker Sensor Error
Ice Maker Kit Defect — Ice Maker Motor Malfunction
Freezer Sensor Error
Pantry / Icing Room Sensor Error